9-1935WAE-PORT (Wideband Access Endpoint Port)

9
Port Audit and Update Test (#36)
This test sends port level translation d ata from switch processor to the UDS1 Interface circuit p ack to ensure that the wideb and access end point port’s translation is correct.
1020 ABORT The test did not run due to a previously existing error on the specific port or
because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or circuit pack,
and attempt to diagnose the previously existing error.
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The NPE of the tested port did not conference the tones correctly. This causes
noisy and unreliable connections. Even though wideband calls do not use the
conferencing feature on the NPE, this failure indicates problems with the circuit
pack hardware.
1. Replace the c ircuit pac k.
PASS The port can correctly conference multiple connections.
1. Investigate user-reported troubles on this port using other port tests and
by examining the terminal adapter or external wiring.
Table 9-717. TEST #7 Conference Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page