1322 ABORT Memory shadowing is off, but not inhibited by the standby SPE.
1. Shadowing may not be turned on yet, so use release spe-standby if the
standby is busied out, wait 5 minutes and run the test again. If the long
duplication-interface demand test was being used , investigate any failure
or abort from test #872 because this test is expected to turn on shadowing.
2. Rerun the test; if the same 1322 abort occurs again, use the display
alarms command and selec t Category spe. If any maintenance objects
other than DUPINT or DUP-CHL have MAJOR alarms, fix these problems.
Problems causing MAJOR alarms for MEM-BD, PKT-INT, SYSAM,
H-ADAPTR, and SW-CTL should be repaired first.
3. Rerun the test; if the same 1322 abort occurs again, look for other DUPINT
or DUP-CHL test failures by using the busyout spe-standby if not already
busied out and the test duplication-interface long clear commands. Fix
these problems according to the service doc umentation for these packs.
4. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the stand by SPE, but don’t replace any circuit
packs.
1325 ABORT Memory shadowing is inhibited from the standby SPE.
1. Shadowing may not be turned on yet, so wait 5 minutes and run the test
again.
2. Rerun the test; if the same 1325 abort occurs again, use the display
alarms command and selec t Category spe. If any maintenance objects
other than DUPINT or DUP-CHL have MAJOR alarms, fix these problems.
Problems causing MAJOR alarms for MEM-BD, PKT-INT, SYSAM,
H-ADAPTR, and SW-CTL should be repaired first.
3. Rerun the test; if the same 1325 abort occurs again, look for other DUPINT
or DUP-CHL test failures by using the busyout spe-standby if not already
busied out and the test duplication-interface long clear commands. Fix
these problems according to the service doc umentation for these packs.
4. If this 1325 abort continues to occur, the standby SPE may not have
initialized properly. Use the lock-and-power-down procedure desc ribed in
Chapte r 5 to powe r down an d power up t h e standby SPE, but don’t replace
any circuit packs.
1405 ABORT This test did not run because the Duplication Channel was busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.