DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-855FIBER-LK (Fiber Link)
9
Expansion Interface Fiber Out-of-Frame (FOOF) Query Test (#238)
This test is non-destructive.
This test is a request to an EI circuit pack to d etermine if it is currently detecti ng
the framing sequence on the i ncoming fiber data stream. If i t cannot detect this
framing signal, the EI circuit p ack will not be able to estab lish a link with the
opposite EI or Switch Node Interfac e circuit pack.
For EI-EI fiber links, this test is run on both EI circuit pack end points of the fiber
link.
PASS The EI circuit pack(s ) have successfully estab lished a link with the opp osite
Expansion Interface or Switch Node Interface circuit pack.
1. If the status port-network command still ind icates that this link is down, it
is possible that one or both of the EI and/or Switch Node Interface circuit
packs have been busied out.
2. If the link still does not come up, reset one or both EI and/or Switch Node
Interface circuit packs on the link.
Table 9-330. TEST #238 Expansion Interface Fiber Out-of-Frame
Query Test
Error
Code Test
Result Description/ Recommendation
1033 ABORT The Expansion Interface circuit pack does not have a fiber link administered to
it. There is not sufficient data to run test. Since the test fiber-link command
was run, the expansion interface should be administered on a fiber link,
therefore this must be a software problem.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Run the test board UUCSS test separately for each Expansion Interface
endpoint on this fib er link and follow the proc edures in the EXP-INTF
section.
Continued on next page
Table 9-329. TEST #237 Expansion Interface Neighbor Query Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page