DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1641TAPE
9
2. Maintenance software in the SPE issues a request to the Host Adapter to
run a checksum on the data p reviously written to the tape.
The Host Adapter reads the data off the tap e and computes a c hecksum
whic h is ret urned to the SPE mainte nanc e softw are.
3. Maintenance software compares the value of the c hecksum from the Host
Adapter with the checksum it previously calculated on the data it stored
on the tape.
Multiple failure conditions c an occur during this test since it uses both the
software and hardware functions used during normal operations.
Table 9-618. TEST #81 0 Tape Write-Read Test
Error
Code Test
Result Description/ Recommendation
1301 ABORT Could not run the testinternal MSS error
1302 1. Retry the command
1304 ABORT Could not allocate the Mass Storage System to run this test. Other application
software may be using it or b ackground maintenan ce tests may be running.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
2. If the test continues to abort, verify that the daily translation-save
operation is not in progress (Use the display system-parameters
maintenance command to display the start time for scheduled
maintenance and the "y/n" option for saving translation daily).
1316 ABORT Could not g et access to the Mass Storage System. O ther application softwa re
may be using it or background maintenance tests may be running.
1. Retry the command at 1-minute intervals for a maximum of 5 retries.
2. If the test continues to abort, verify that the daily translation-save
operation is not in progress (issue the display system-parameters
maintenance command to display the time for scheduled maintenance
and the "y/n" option for saving translation daily).
1335 ABORT Could not run the test on the Standby SPEDuplication not administered.
1. Refer to the documentation for STBY-SPE maintenance.
2. Administer standby present.
1338 ABORT Could not run the test on the Standby SPEInterchange pending.
1. Refer to the documentation for STBY-SPE maintenance.
2. After interchange occurs, run test on new active SPE.
Continued on next page