Maintenance Object Repair Procedures
9-1806TONE-PT (Tone Generator)
9
FAIL The Tone Generator could be defective. In a Port Network with more than one
Tone-Clock circuit pack, the system will attempt to move the tone generation
function to the alternate one.
1. Test the Tone-Clock circuit pack again via the test tone-clock UUC
command.
2. If the test fails again, look at the Hardware Error Log for Tone Detector
circuit pack errors.
3. If there are Tone Detector circuit pack errors, refer to Tone Detector
Maintenance documentation (DTMR-PT, GPTD-PT, CLAS-PT, ETR-P T) to
resolve these errors first.
4. If there are no Tone Detector circuit pack errors, then the Tone-Clock circuit
pack should b e replaced. See
How to Replace the Tone-Clock Circuit Pack
in the TONE-BD section.
PASS The tone generation facility is able to put tones out.