DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-404CLSFY-BD (Call Classifier Circuit Pack)

9
CLSFY-BD (Call Classifier Circuit
Pack)

Refer t o “XXX-B D (Com mon Por t Circ uit Pa ck)” for circ uit p ack level errors . See

also “Call Classifier Port (CLSFY-PT)” for related port information.

MO Name (in
Alarm Log) Alarm
Level Initial Command to
Run1
1. 4UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides
(01 to 21).
Full Name of MO
CLSFY-BD MIN test board UUCSS sh Call Classifier Circuit Pack
CLSFY-BD WRN test board UUCSS sh Call Classifier Circuit Pack