DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-811EXP-INTF (Expansion Interface Circuit Pack)
9
1033 ABORT The EI circuit pack does not have a fiber link administered to it. There is not
sufficient data to run test.
1. Issue the list fiber-link command to verify that there is no fiber link
administered to this circuit pack.
2. If there is no fiber administered to this circuit pack, but there should be
add the correct fiber using the add fiber-link command.
3. Retry the command.
1394 ABORT The EI circuit pack is out of service and the test cannot be run. This condition
is due to a change in the EI circuit pack’s ability to communicate with the EI or
Switch Node Interface circuit pack on the other end of the fiber.
1. Run Test #237 and check the Error Log for EXP-INTF error type 1281. If
error type 1281 is present or if Test #237 does not pass, refer to repair
procedures for Test #237.
1395 ABORT This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
Duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the
change system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 3 times.
Table 9-310. TEST #240 Expansion Interface Local Looparound — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page