DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1121M/T-PKT (Maintenance/Test Packet Bus Port)
9
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. This error indicates a hardware failure with the por t circuitry which
provides the Packet Bus maintenanc e functions. Replace the
Maintenance/Test circuit pack if the alarm i s not resolved by the test
command above.
b. The port has been busie d out via the busyout port UUCSSpp command.
c. This error indicates that the Maintenance/Test Packet Bus Port has
reconfigured the Packet Bus by swapping a bad lead to a spare. Note that
this error is sent up whenever the Maintenance/Test Packet Bus Port is
initialized (since the Packet Bus Port rec onfigures the Packet Bus to
whatever state it determines the Packet Bus is in). This will oc cur if the
circuit pack is inserted, if the system is restarted, or if the port is released
from a busyout state. Therefore, it is normal for this error to be p resent in
the error log.
If the M/T-PKT reconfigures the Packet Bus 6 times within 15 minutes, a
Minor alarm is raised indic ating that either Packet Bus maintenance
functions are not operating correctly, or many changes are taking p lace on
the Packet Bus (circuit pac k insertions or removals). If the system has
been in a stable state for more than 15 minutes, try the following
procedure:
M/T-PKT Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSpp
1 (a) 4 1018 none MINOR ON test port UUCSSpp l r 3
18 (b) 0 busyout port
UUCSSp p WARNING OFF release port UUCSSpp
257 (c) Any none MINOR ON
513 (d) Any Packet Bus Port
Health Inquiry
Test (#567)
MINOR ON test port UUCSSpp r 3