DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Additional Maintenance Procedures
6-39Removing and Restoring Power
6
The three test types should have extension numb ers assigned on the
Maintenance-Related System Parameters Form.
Test Type 100:___ Test Type 102:___ Test Type 105:___
Test Type 100 provides:
5.5 seconds of 1004 Hz tone at 0d B
Quiet until disconnect; d isconnect is forced after one minute
Test Type 102 provides:
9 seconds of 1004 Hz tone at 0dB
1 second of quiet
This cycle is repeated until d isconnect; disc onnect is forced after 24
hours.
Test Type 105 provides:
9 seconds of 1004 Hz at -16dB
1 second of quiet
9 seconds of 404 Hz at -16dB
1 second of quiet
9 seconds of 2804 Hz at -16dB
30 seconds of quiet
1/2 second of Test Progress Tone (2225 Hz)
Approximately five second s of quiet
Forced disconnec t
Removing and Restoring Power
!CAUTION:

Error Log information is lost when the PPN cabinet is powered down. If this

information is to be saved, ent er the reset system 4 command. The

command will take several minutes to c omplete, and will result in saving of

the Error Log to the MSS.

!CAUTION:

Before powering down a c abinet or carrier that contains DEFINITY AUDIX

circuit packs (TN566 and TN2169), you must first power down the AUDIX

unit to avoid damage to th e AUDIX software Instructions for powering d own

this unit appear on the circ uit pack and in DEFINITY AUDIX documentation.