Maintenance Commands
8-111display system-parameters maintenance
8
Modem Connection
On page 3 of the example for ms shown below, there are 11 fields that are hidd en
when the Modem Connection? field is set to internal. In this example the
Modem Connection field is set to external, and these ad ditional 11 fields are
visible.
The first 2 fields on page 3 help setup the d ata format for the serial data from the
switch to the modem.There are only two valid c ombinations for these 2 fields:
Data Bits = 8, Parity = None
Data Bits = 7, Parity = (odd , even, mark, or space)
The remaining fields are listed below:
Loss Plan Use only when extra loss is required to maintain quality of
transmission on conference c alls. Leave this field blank if no
extra loss is required. If extra loss is req uired, enter digits as
shown below.
No. Of Parties To
Be Conferenced Enter Digit
32
43
54
65
76
SPE Optional
Boards: These fields indicate whether a Disk c ircuit pack is p resent in the
system, and which Packet Interfac e slots are administered. If a
Packet Interface circuit p ack is physica lly present, the
corresponding Packet Interface field is set to y when the s ystem
boots, and no chang e to that field is allowed. If the sys tem is
equi ppe d wi th du plic ated SPEs, a Packe t Inte rfac e fie ld is set to y
when either SPE carrier contains a Packet Interface circ uit pack in
the corresponding position. If a Packet Interface circ uit pack is not
present, then the value for the Packet Interface field is read from
translation data stored on disk or ta pe. If the field is set to n, a
Packet Interface circuit p ack may be administere d by changing the
corresponding Pac ket Interface field to y.
Modem
Connection Internal or external (internal)
Modem Name This field is 20 characters long and will permit alp ha-numeric
characters to provid e a unique qualifier for a g iven modem. ( )