DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-926HYB-LINE (Hybrid Line)
9
Table 9-356. TEST #62 Hybrid Line Ringer Update Test
Error
Code Test
Result Description/ Recommendation
3 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
Error Type is present, release the port via the release station
<extension> command and run the test again.
2. Make sure that the termin al is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a t for the port).
2. If either list config or display port indicate that the port is
not
a TTI port,
escalate the problem. If both commands indicate that the p ort is a TTI
port, the abort is correct, and no action is necessary.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Hybrid Station Ringer Update passed
1. If complain ts still exist, investigate using other circuit pac k tests on this
circuit pack, and by examining the terminal, wiring, and c onnections.