DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-320test alarms
8
Error Messages
If the command entered is in confli ct with another currently executing command,
then a message will be d isplayed showing the log in id of the conflic ting user and
the conflicting c ommand. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a c ommand a resource p roblem occurs that req uires
the user to restart the command, then the follow ing message will be d isplayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resourc es are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
Query From Input
After entering the command test alarms, the system technician will b e presented
with an options form for alarm selec tion.
Alarm
Types The type of alarm to be tested is sp ecified by p lacing a ’y’ or ’n’ in the
alarm type fields. The technic ian can choose a comb ination of active
alarms: major, minor, and/or warning.
Interval Test alarms for records for the last hour (h), last day (d), last week (w) or
all (a). The default is all.
From Test alarm associated with record s from the time specified by
mm/dd/hh/mm, where mm month, d d is the day, hh is the hour and mm is
the minute. If no “from” date i s entered, then no checking is done. This will
give the user all the alarms active sinc e a month prior to the current time.
To Test alarms associated with record s to the time specified by
mm/dd/hh/mm, where mm is the month, d d is the day, hh is the hour and
mm is the minute. If no "to" date is entered, any alarm which is active after
the from date will be selec ted.