DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1181PE-BCHL (PRI Endpoint Port)
9
Table 9-468. PRI Endpoint Port Service States
Service
State1Alarm Possible Cause Possible Solution
OOS/NE
Warning Port has been busied out
by comma nd. Enter release pri-endpoint extension.
Minor NPE Crosstalk Test (#6)
failed. Replace UDS1 circuit pack.
UDS1 circuit pack lost its
signal. Is the UDS1 circuit pack removed? Is the
UDS1 cable disconnected? Is the far-end
terminal restarting or experiencing
problems? Check c ircuit pack using
procedures UDS1-BD.
OOS/FE
Warning Far-end problems or
incompatibility Check administration and status of the
corresponding port on the terminal
adapter.
Warning The far-end port is busied
out. Check the status of the far-end terminal
adapter.
OOS/FE
PINS
Service message was
sent and the switch is
waiting up to 2 min. for a
reply from the far-end
terminal adapter.
Wait 2 min. and check service state after
the PINS state has cleared.
MTC/NE System link demand
busied out Check link status. Release with release
link link#.
MTC/FE Warning Signaling channel has
been down for over 90
sec.
Consult ISDN-SGRP, ISDN-LNK and/or
SYS-LINK. Far-end terminal adapter may
currently be restarting.
Warning Repeated failure of far
end to respond to
messages.
Maintenance software will periodically try
to resend messages. You can speed the
process with test port UUCSSpp (Test
#256).
Warning The far-end port is being
tested. Check status of the far-end terminal
adapter.
MTC/FE
PINS Service message was
sent and the switch is
waiting up to 2 min. for a
reply from the far-end
terminal adapter.
Wait 2 min. and check service state after
the PINS state has cleared.