DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-282ATM-TRK (Circuit Emulation Service Circuit Pack)
9
Table 9-129. ATM Board DSP Test (#1293)
Error
Code Test
Result Description/ Recommendation
1002 ABORT Could not allocate time slots. Traffic may be heavy or time slots may be
out-of-service
1. Run display errors, and follow associated repair procedures for
TDM-BUS.
2. Retry the command up to 3 times at 1-minute intervals.
1003 ABORT Could not allocate a tone detector. Too few tone detectors present or tone
detectors out-of-service.
1. Run display errors, and follow the repair procedures associated with
any TTR-LEV errors that appear.
2. Make sure that there is at least one tone detector on the network that
holds the ATM-TRK circuit pack.
3. Resolve any TONE-PT errors listed in the Error Log.
4. Retry the command up to 3 times at 1-minute intervals.
1962 ABORT All DSPs are busy. This is a very unlikely event.
1. Retry the command up to 3 times at 1-minute intervals.
2000 ABORT Test timed out.
1. If the ATM-TRK circuit pack is in standby, reset the board and run the
test again after the ATM-TRK circuit pack is inserted.
2. Examine the Error Log for Error 1218 (bad DSP).
3. Run the test again.
2100 ABORT Could not allocate required system resources.
2302 ABORT Inconsistent uplink message from the ATM-TRK circuit pack.
2500 ABORT Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
2752 ABORT Circuit pack not a TN230x.
Continued on next page