DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-280ATM-TRK (Circuit Emulation Service Circuit Pack)

9
ATM Board Time Of Day Update (#1261)

The non-destructive ATM-TOD-UPD test updates the system time that the

ATM-TRK circuit pack uses for SDH/SONET performance monitoring and

synchronizes the ATM-TRK circuit pack with the DEFINITY system clock. This test

is run during initialization, sc heduled maintenance, and craft long test.

6 FAIL A previously establishe d looparound was not re leased.
1. Run reset board UUCSS.
2. Retry the command up to 3 times at 1-minute intervals.
3. If this test continues to fail, replace the ATM-TRK circuit pack.
4. Rerun test board UUCSS long.
PASS The non-optical parts of the ATM-TRK circuit pack are functioning properly.
0NO
BOARD ATM-TRK circuit pack not found
1. Check the error log for Error 125 (wrong board) or Error 131 (no board),
and correct as necessary.
2. Check that the board is properly translated and inserted .
3. Check for Error 1538 (hyperactivity), and run reset board UUCSS if
necessary.
4. Rerun test board UUCSS long.
5. If the test fails, replace the board, and rerun test board UUCSS long.
Table 9-127. ATM Board Framer Looparound Test (#1260) — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page