DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-165monitor system
8
Output
The following output fields are for the monitor system conn c ommand.
Time Slot
Status There are 4 numbers associated with the ti me slot status for each
specified p nn; for each of the two buses (0 and 1) there is a
maintenance and a normal state. The first row is the p nn, the
second spec ifies the bus while the third sp ecifies the bus’s state
while the last column represents the n umber of idle counts. These
fields represent real-time status data.
Bus Status For the bus status fields, there are two numb ers associated with
each of the two buses for eac h pnn. Shown are the pnn number;
the bus associated with i t, i.e., 0 or 1; and the state of the bus, i.e.,
“avail” or “unavail” . These fields represent real-time status d ata.
Callrate The callrate field represents the c all rate being experienc ed
currently on the switch. This is a counter which is bumped each
time a call attempt is mad e. This field represents real-time status
data.
Interval This field is related to the above field in that it represents the
interval being app lied with which the cal l rate is applicab le. It is
normally set to a 36 second time p eriod. This field represents a
constant status data.
Max_callrate This field represents the maximum ca ll rate which has been hit
during the time since the last hour has passed. If, for examp le, at
20 minutes past 12:00 this command is executed, this field will
represent the maximum call rate ob tained during the p ast 20
minutes. This field represents real-time status data.
Next_hour This field will contain a value of 0 or 1 de pending upon if the
measurements being taken are for thi s hour or the next. It is related
to the previous field in that the maximum call rate is reflected for
this hour. When this flag is set, then statistics b egin to accumulate
for the next hour and shortly thereafter, the maximum c all rate will
become zero and ac cumulations will beg in anew.
tot_ts_req This field holds the total time slots in use d uring the time period
elapsed since the top of the last hour. Data is internally collec ted
every 100 seconds. When the timer fires and the data collection
occurs, a check is made as to how many time slots are currently in
use. That’s where the total comes from. There are three numbers
displayed for this field on the form; one for each of the p nns
requested. This field represents real-time status data.
ts_denied This field holds the total time slots req uests that were denied d uring
the time period elapsed since the top of the last hour. Data is
internally collected ev ery 100 seconds. There are three numbers
displayed for this field on the form; one for each of the p nns
requested. This field represents real-time status data.