Maintenance Object Repair Procedures
9-1526STO-DATA (Stored Data)
9
3. Run test stored-data to retire the alarm.
4. If the Stored Data tests fail, refer to the repair proce dures for those
tests.
j. Error types 3586 and 3842 indic ate that an attempt to restore the disk from
tape failed on carrier A or B, resp ectively.
1. Refer to the alarm log and clear a ny H-ADAPTR, DISK, TAPE, or
DUPINT alarms first.
2. Enter restore disk. This operation may take up to an hour.
3. Run test stored-data to retire the alarm.
4. If the Stored Data tests fail, refer to the repair proce dures for those
tests.
k. Error types 3587 and 3843 indic ate that an attempt to bac kup the disk to
the tape failed on carrier A or B, respectively.
1. Refer to the alarm log and clear a ny H-ADAPTR, DISK, TAPE, or
DUPINT alarms first.
2. Enter backup disk. This operation may take up to an hour.
3. Run test stored-data to retire the alarm.
4. If the Stored Data tests fail, refer to the repair proce dures for those
tests.
System Technician-Demanded Tests
The seq uen ce of tests per form ed d epe nds o n whe ther t he SPE is dup lic ated .
Always investigate tests in the order p resented in the table belo w when
inspecting errors in the sys tem. By clearing error cod es associated with the

A

Carrier Tape Checksum Test

, for example, you may also clear errors g enerated
from other tests in the testing sequence.
Short Sequence Long Sequence
SPE: Simplex Duplex Simplex Duplex
MSS (D:disk/tape, T:tape only) D T D T D T D T
A Carrier Tape Checksum Test (#829) X X X X
B Carrier Tape Checksum Test (#830) X X
A Carrier Disk Checksum Test (#831) X X
B Carrier Disk Checksum Test (#832) X
A Carrier Tape to Disk Consistency Test
(#833) XXXX