DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1697TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
9
The test fails if the board is not inserted, if there is an internal system error, or if a
reply was not received within the p rescribed amount of time.
The test aborts if the signaling link is d isconnected, the request is already active ,
or if the B-Channel is in an Out-Of-Service state.
ISDN Test Call Test (#258)
This test performs a far-end loop around to a far-end switch over an ISDN trunk.
The trunk’s service state must be in-service , maint-NE, or out-of-service/NE, and
no call can be ac tive on the trunk.
A test call connection is es tablished to a far-end switc h over the ISDN trunk to be
tested. The digital por t on a TN711D Maintenance/Test circuit pack genera tes a
test-pattern bit stream that is sent to the far-end switch and echoed back. The
received pattern is then compared to the sent pattern and checked for errors that
indicate a loss of integri ty on the communications p ath.
Table 9-638. TEST #257 Call State Audit Test
Error
Code Test
Result Description/ Recommendation
1018 ABORT The test is disabled.
1. Enable the test by entering y in the Maintenance Tests? field on
page 2 of the change trunk-group form.
1019 ABORT An audit is already in progress.
1. Wait two minutes and try again.
1113 ABORT The signaling link has failed, so the system cannot send any messages on
behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State Check).
1114 ABORT The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1116 ABORT The trunk is in an out-of-service ISDN servic e state.
1. A call cannot be present if the trunk is in an ISDN out-of-service state,
so a call state audit would be inappropriate. No action necessary.
(Use the status trunk command.)
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The audit passed suc cessfully.
Continued on next page