DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1750TIE-DS1 (DS1 Tie Trunk)
9
1000 ABORT System resources required to run this test were not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
2. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of this
error and required actions). The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1006 ABORT The test was aborted because th e trunk is out of service.
1. Use the status trunk command to verify that the trunk is out of service.
2. If the trunk is out of service, d etermine why.
3. If it is OK to put the trunk back in service, issue the release trunk
command to put the trunk back in service, and then retry the test.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS Trunk translation has been updated successfully. The current trunk states kept
in the DS1 Interface circuit pack and switch software are consistent. If the trunk
is busied out, the test will not run but will return PASS. To verify that the trunk is
in-service:
1. Enter the status trunk command to verify that the trunk is in-service. If the
trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to step 2.
2. Enter the release trunk command to put the trunk back into in-service.
3. Retry the test command.
Table 9-655. TEST #36 Audit and Update Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page