DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-941ISDN-LNK (ISDN-PRI Signaling Link Port)
9
1139 ABORT The Packet Bus in this port network is out-of-service.
1. Follow repair procedures for the Packet Bus.
2. Enter test port UUCSSpp long command and chec k results of this test
(#939).
1141 ABORT The Packet Interface c ircuit pack is out-of -service.
1. Follow repair procedures for PKT-INT.
2. Enter test port UUCSSpp long command and check results of this test
(#939).
1144 ABORT The Packet Bus in the PPN is out-of-service.
1. Follow repair procedures for the Packet Bus.
2. Enter test port UUCSSpp long command and chec k results of this test
(#939).
2012 ABORT Internal system error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The Loop back Te st has fa iled.
1. If the test fails repeatedly, attempt to reset the circuit pack when the
other ports on the board are not in use. Reset the circuit pack by
entering busyout board UUCSS and reset board UUCSS.
2. Repeat the test and, if it continues to fail, replace the circuit pack.
PASS Connectivity of the D-channel over the Packet Bus is operational.
Table 0-2. TEST #939 Signaling Port LAN Loopback — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page