DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-768ETH-PT (Control LAN Ethernet)
9
Table 9-298. TEST #1281 TCP/IP PING Test
Error
Code Test
Result Description/ Recommendation
1, 2 ABORT Internal error
1. Retry the command at 1-minute intervals a maximum of 3 times
7 ABORT Destination unreachable.
1. Verify that at least one destination reachable through this port is up.
Once verified, test the port again (test port UUCSS) verify that the
TCP/IP Ping Test (#1281) passes.
1005 ABORT Incorrect test configuration.
1. Verify Ethernet link is in service (status port UUCSSpp or status link
n).
2. Verify that Ethernet link is enabled (status port UUCSSpp or status
link
n
or display data-module).
3. Verify routing table has reachable destinations.
4. Repeat the test.
5. If problem p ersists while the Ethernet link is in servic e and enabled,
escalate the problem.
1124 ABORT Ethernet link is not enabled .
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status
link
n
, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
1125 ABORT Ethernet link not in service .
1. Verify Ethernet link is in service (status port UUCSSpp or status link
n).
2. If the link is not in service, release the link using (release link n or
release port UUCSSpp).
3. Repeat the test.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. Reset the circuit pack (busyout port UUCSSpp and reset board
UUCSS).
2. If the test fails again, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
Continued on next page