DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Alarms, Errors, and Troubleshooting
5-50ATM Tips
5
—The
POLL PDUs and STAT PDUs counters should b e increasing if
the TN230X is actively sending and rec eiving Q.SAAL Protocol
Data Units with the A500. This occurs even if the TN230X did not
achieve board insertion.
Q.93B (Network) Layer
Are connection requests being received by A500 Call Control?
1. Enter show signaling stats
port
q93b (or the port of interest) on the A500
console. Figure 5-29 shows the screen output.
Figure 5-29. A500:show signaling stats A1.2 q93b
NOTE:
If there is no connection betwee n the TN230X and the A500 at the
Q93B protocol layer, then no report displays.
Ensure that the fields have the values indicated below.
Port
A1.2
(or the
port of
interest)
If this field is not configured for UNI signaling,
then the port was administered for no UNI signaling
(admin link command). Use the show signaling
summary command to verify that Signaling is UNI3.1.
A500:show signaling stats a1.2 q93b
-------------------------Q.93B Statistics------------------------
Port A1.2:
----------
Tx Rx
-------- --------
Connect Messages: 15 18
Setup Messages: 18 15
Release Messages: 17 13
Rel Cmplt Messages: 13 17
Add Party Messages: 0 0
Add Party Acks: 0 0
Add Party Rejects: 0 0
Drop Party Messages: 0 0
Drop Party Acks: 0 0
Last Cause Code: 31 31
Last Diag Code: 0. 0. 0 71. 0.29
Total Connections: 33
Current Connections: 3