NOTE:
Many trunk problems are caused by incorrect setting s of parameters on the
trunk group administra tion form. Settings must be comp atible with the local
environment and with parameter setting s on the far-end. Refer to

DEFINITY.

Enterprise Communications Server Release 5.4 Administration and Feature

Description
, for information on how to administer trunks. The App lication
Notes section of that book shows the c orrect settings for administrab le
timers and other parameters on a c ountry-by-country ba sis.
Direct Inward Dial trunks connec t the switch to the CO, and allow outsid e parties
to call directly to an extension in the system. DID trunk circuit pac ks support
eight incoming-only p orts. Each port provid es an interface between the 2-wire
analog CO line and the 4-wire TDM bus on the switc h.

DID Trunk Operation

The DID port receives three to five dig its from the CO that are used to directly
connect an outside c aller to the called station without assis tance from an
attendant. For each call, the CO switc h signals the system by openi ng and
closing individ ual DID loops (one of the eight p orts), causing the starting or
stopping of loop current.

DID Trunk Testing

The system uses four tests of on-board circ uitry to diagnose the health of the
trunk. These are described in the following sections. Add itionally, in-line testing
which can generate errors, is performed while a c all is in progress. See the Error
Log table for a desc ription of these errors. These errors may be reprod uced by
placing a c all on the trunk and checking the Hardware Error Log.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run1
1. UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier designation
(A, B, C, D, or E). SS is the number of the slot i n whi ch the circuit pack resides (01 to 21). pp
is the two digit port number (01, 02, ...).
Full Name of MO
DID-TRK MAJOR2
2. A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by the
set options command and that at least 75 percent of the trunks in this trunk group are
alarmed.
test port
UUCSSpp
l DID Trunk
DID-TRK MINOR test port
UUCSSpp
l DID Trunk
DID-TRK WARNING Non e DID Trunk