DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1233PGATE-PT (Packet Gateway Port)

9
Session Restart Test (#977)
This test is destructive.

This test destroys and attempts to restart all the sessions on the X.25 Access Link

associated with the Packet Gateway p ort.

The test attempts to restart all the sessions as long as th ere is at least one

session down on the link. This test aborts if the all th e sessions are up.

2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
1 FAIL At least one (but not all) sessions on the X.25 access link associated with the
Packet Gateway Port are down. Same recommendation as for error type 1537.
2 FAIL All sessions on the X.25 access link associated with the Packet Gateway Port
are down. Same recommendation as for error type 1538.
PASS All sessions on the X.25 access link associated with the Packet Gateway Port
are up.
Table 9-493. TEST #977 Session Status Query Test
Error
Code Test
Result Description/ Recommendation
ABORT All sessions are up. This is a NORMAL ab ort.
1124 ABORT The X.25 access link associated with this Packet Gateway Port is not enabled.
1. Check if the X.25 access link is enabled for this Packet Gateway Port. If
the ‘‘enable’’ field on ‘‘display communication-interface link’’ form is ‘‘n’’
for the link entry which contains the data module extension associated
with the Packet Gateway Port, then the X.25 access link is not enabled.
Set the field to ‘‘y’’ using change communication-interface link
command and repeat the test. This is a NORMAL abort.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-492. TEST #976 Session Status Query Test Continued
Error
Code Test
Result Description/ Recommendation