DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1232PGATE-PT (Packet Gateway Port)

9
Session Status Query Test (#976)
This test is non-destructive.

This test determines the state of the sessions on the X.25 Acc ess Link associated

with the Packet Gateway port.

This test determines if all the sessions associated with the channels using the

X.25 Access Link is up or d own. This test passes if the all the sessions are up

and fails otherwise.

2 FAIL The X.25 Access Link is disconnected.
1. Execute the Packet Gateway Port Local Loop-Around Test (#610) and the
Level 1 State Query Test (#613) via the test port UUCSSpp long
command. Consult the repair procedures for these tests.
2. If all tests pass, check far-end switch equip ment. Execute the Packet
Gateway Port Remote Loop-Around Test (#611) via the test port
UUCSSpp long command. Consult the repair procedures for this test.
3. If test #611 pass es, see the repair proc edures for the Packet Control c ircuit
pack and the Packet Bus.
PASS The X.25 Access Link is connected.
Table 9-492. TEST #976 Session Status Query Test
Error
Code Test
Result Description/ Recommendation
1124 ABORT The X.25 access link associated with this Packet Gateway Port is not enabled.
1. Check if the X.25 access link is enabled for this Packet Gateway Port. If the
‘‘enable’’ field on ‘‘di splay communicat ion-interface link’’ form is ‘‘n’’ fo r the
link entry which cont ains the data module extensi on associated with the
Packet Gateway Port, then the X.25 access link is not enabled. Set the fiel d
to ‘‘y’’ using change communication-interface link command and repeat
the test. This is a NORMAL abort.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-491. TEST #614 Link Status Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page