DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1749TIE-DS1 (DS1 Tie Trunk)
9
Port Audit and Update Test (#36)
This test sends port level translation d ata from switch processor to the DS1
Interface circuit p ack to ensure that the trunk’s translation is c orrect. Translation
updates includ e the following data: trunk typ e (in/out), dial type, timing
parameters, and signaling bits enabled. The port audit operation verifies the
consistency of the current sta te of the trunk kept by the DS1 Interface c ircuit
pack and the switc h software.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list config
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-e stablish the linkage
between the internal ID and the port. If this is not the case, check to see
that there is a valid board inserted.
Table 9-655. TEST #36 Audit and Update Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-654. TEST #7 Conference Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page