DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-712DUP-CHL (Duplication Interface)
9
1411 ABORT This test did not run because the standby Duplication Interface c ircuit pack
cannot be detected as b eing plugged in b y the software.
1. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the stand by SPE, but don’t replace any circuit
packs.
2000 ABORT This test did not run because communication with the standby timed out while
waiting for a reply to a ma in tenance message instruc ting it to disallow memory
shadowing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the standby SPE, but don’t replace any circuit
packs.
2334 ABORT The hardware mailbox in the standby Duplication Interface circuit p ack is not
ready to receive messages.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure describ ed in Chapter 5.
to power down and power up the standby SPE, but don’t replace any circuit
packs.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The expected interrupt that indicates shadowing has been turned off in the
standby SPE was not received after this test had instructed the standby SPE to
turn off shadowing.
1. Replace Duplication Interface comp onents starting with the standby
Dupl icati on Int erfac e ci r cuit pac k . Use SPE D upli catio n Chan nel
Component Replacement procedures at the end of this DUP-CHL section.
54 F AIL The attempt to turn on memory shadowing in this DUPINT circuit pack could not
be verified in the DUPINT hardware status register.
1. Replace Duplication Interface comp onents starting with the standby
Dupl icati on Int erfac e ci r cuit pac k . Use SPE D upli catio n Chan nel
Component Replacement procedures at the end of this DUP-CHL section.
PASS The interrupt that indica tes shadowing has b een turned off in the stand by SPE
was received after this test had instructed the standby SPE to turn off
shadowing.
Table 9-275. Test #872 Memory Shadowing Disable Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page