DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-864FIBER-LK (Fiber Link)
9
108 FAIL The SNI circuit pack (endpoint 1) cannot communicate with the equipp ed SNI
in slot 8 (list fiber-link can be used to display fiber link endpoints).
1. Perform the ‘‘Fiber Fault Isolation Procedure’’. This sh ould resolve multiple
SNI-PEER err ors..
2. If the SNI being tested has SNI-PEER Error Type 1537, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 1537, replace the SNI
in slot 8.
109 FAIL The SNI circuit pack (endpoint 1) cannot communicate with the equipp ed SNI
in slot 9 (list fiber-link can be used to display fiber link endpoints).
1. Perform the ‘‘Fiber Fault Isolation Procedure’’. This sh ould resolve multiple
SNI-PEER err ors.
2. If the SNI being tested has SNI-PEER Error Type 1793, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 1793, replace the SNI
in slot 9.
112 FAIL The SNI circuit pack (endpoint 1) cannot communicate with the active SNC (list
fiber-link can be used to display fiber link endpoints).
1. Check the error log for other SNI circuit packs in the same carrier with a
257 SNI-BD error. Use display errors with category PNC to view SNI-BD
errors. If other SNI circuit packs in the same switch node carrier have error
257, then replace the ac tive SNC in this switch node c arrier. Replacing an
SNC may be service interrupting. Refer to the SNC-BD section for the
procedure for replacing an SNC.
2. Replace this SNI.
3. Replace the active SNC in the same switch node carrier.
Table 9-333. TEST #759 Configuration Audit — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page