DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-292AUX-TRK (Auxiliary Trunk)
9
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-ser vice.
1. Resolve TTR-LEV errors.
2. Resolve TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the status tr unk command to
determine the servic e state of the port. If the port i s in use, wait until the
port is idle.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2020 ABORT The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the previously existing error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Any FAIL The Network Processing Element (NPE) of the tested port was found to be
transmitting in error. This will c ause noisy and unreliable conn ections. This
problem may be caused by d efective tone detectors.
1. Test all tone-clock circuit packs, and resolve any errors on these circuit
packs before any action is taken on the auxiliary trunk circuit pack.
Then, repeat the test.
2. If the test fails again, replace the auxiliary trunk circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troub les on
this port should b e investigated using other p ort tests and examining
station, trunk, or external wiring.
Table 9-132. TEST #6 NPE Crosstalk Test — Continued
Error
Code Test
Result Description/Recommendation
Continued on next page