Looparound and Conference Test (#33)

This test checks the reflective loop around and conferenc e capabilities of an

auxiliary trunk port circ uit. The test uses 404-Hz, 1004-Hz, and 2804-Hz tones.

Each tone is separately transmitted through the loop and c hecked. All of these

tests are performed on-board.

Table 9-133. TEST #33 Looparound and Conference Test
Error
Code Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use th e status trunk command to
determine the servic e state of the port. If the p ort is in use, wait until the
port is idle.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use th e status trunk command to
determine the servic e state of the port. If the p ort is in use, wait until the
port is idle.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
7 FAIL The conference capabilities of the p ort failed.
1. If no service problems exist on the port, continue to use the port until
the circuit pack can be replac ed.