DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1422SNC-LINK (Switch Node Clock Link)
9
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table below when
inspecting errors in the sys tem. By clearing error cod es associated with the
configuration audit
for example, you may also clear errors g enerated from other
tests in the testing sequenc e.
Refer to maintenance object SNC-BD for desc riptions of tests and results.
Order of Investigation Short Test
Sequence Long Test
Sequence Reset Board
Sequence D/ND1
1. D = Destructive, ND = Non-d estructive
Configuration Audit (#759) X X ND
Failure Audit(#777) X X ND
Processor Route Audit(#760) X ND
SNC On-Board Test(#778) X X ND
TPN test(#779) X X ND
Switch Node Clock Reset Test(#780) X D