Maintenance Object Repair Procedures
9-1850UDS1-BD (UDS1 Interface Circuit Pack)
9
1301 FAIL The 120A1 CSU Module is physically connected to the TN464F board on the
back of the port carrier but the
Near-End CSU Type
field on the
add ds1
form
has not been administered as
integrated
.
1. If the 120A1 CSU Module is to be used , use the
change ds1
command to
change the
Near-End CSU Type
field to
integrated
. Otherwise, physically
remove the 120A1 CSU Module from the back of the port carrier.
2. Run the test again.
1302 FAIL Attempting to use the 120A1 CSU Module with a TN464F circuit pack that is
configured for 32-channel (2.048 Mbps) operation. The CSU Module only works
with a DS1 board config ured for 24-channel (1.544 Mb ps) operation in the
United States of America.
1. If the 120A1 CSU Module is to be used, physically remove the TN464F
circuit pack and reconfigure for 24-channel (1.544 Mbp s) operation.
2. Reinsert the circuit pack and run the test again.
1303 FAIL The DS1 circuit pack Suffix is incorrect for CSU Module administration. The
Near-End CSU Type
field on the
add ds1
form has been administered as
integrated
but the DS1 circuit pack is not a TN464F or later suffix UDS1 board.
1. If the CSU Module is to be used, and the
Near-End CSU
Type field is set to
integrate to allow for CSU Module administration, remove the circuit pack
and replace it with a TN464F or later suffix board. Otherwise use the
change ds1
command to change the
Near-End CSU Type
field to
other
.
1310 FAIL The DS1 Board Loopback (BLB) demand test (#1209) failed.
1. Repeat the test using the
test ds1-loop UUCSS ds1/csu-loopback-tests
command.
2. If the BLB test continues to fail, then replace the TN464F circuit pack.
3. Run this test again.
Table 9-687. TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page