DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-814EXP-INTF (Expansion Interface Circuit Pack)
9
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out of service.
1. Enter display errors and follow associated repair procedures for TTR-LEV
errors in the error log. Even if there are not TT R -L E V errors, there may not be
a tone detector available on the network that contains the circuit pack being
tested. Verify that there is at least one tone detector on this network. If not,
this test will always abort for this EI circuit pack. This will not harm the
system in any way.
NOTE:
DEFINITY Systems require that Tone Detector circuit packs (TN768) must
be of vintage “B” or newer. If older Tone Detector circuit packs are
installed in the system, this test will always abort with this code.
2. Enter display errors and follow associated repair procedures for TONE-PT
errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 3 times.
1033 ABORT The test cannot run because either the EI board does not have a fiber link
administered to it and there is not sufficient data to run the test, or there were no
other PNs administered that had its EI board In-Service.
1. Check fiber administration to insure that there is a fiber link administered to
this Expansion Interface circuit pack.
2. If there is a fiber administered to this EI circuit pack, then some change in
the status of the ability of the EI circuit pack in the other PNs to
communicate with the EI or Switch Node Interface circuit pack on the other
end of its fiber has occurred.
3. Test #237 and check for EXP-INTF circuit pack Error Type 1281 in the Error
Log for the EI circuit packs in these other PNs. If Error Type 1281 is present
and/or Test #237 does not pass, refer to repair procedures for Test #237.
4. If Test #237 passes, reseat the EI circuit pack. This is not destructive since
the circuit pack cannot be serving as the Expansion Archangel if it is not in
service.
1394 ABORT The Expansion Interface circuit pack is out of service and the test cannot be run.
This condition is due to a change in the EI circuit pac k’s ability to communicat e
with the EI or Switch Node Interface circuit pack on the other end of the fiber.
1. Run Test # 237 and c heck t he Error Lo g for EXP-IN TF Error Type 1 281. If
Error Type 1281 is present or if Test #237 does not pass, refer to repair
procedures for Test #237.
Table 9-311. TEST #241 Expansion Interface 2-way Transmission Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page