DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-114ANN-PT (Announcement Port)
9
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates that the c ircuit pack has b een removed or has
been insane for more than 11-minutes. To clear the error, reinsert or
replace the circuit pack.
b. This error is logged and the port is alarmed when an alar m is raised on the
announcement circuit p ack because of a faulty condition with a common
circuit pack resourc e. Any one of the following alarmed errors on the
announcement circuit p ack causes this error to be l ogged against t he
Announcement Port: 1793, 2049, 2305, 2561. See β€˜β€˜ANN-BD
(Announcement Circuit Pack)’’ to resolve these alarm s. When the
corresponding circuit pack alar m is cleared, this alarm will c lear.
Table 9-44. Announcement Port Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test port UUCSSpp sh r 1
1 Playback Speec h
Memory Array
(PSMA) Test (#206)
MINOR ON test port UUCSSpp sh r 3
18 0 The port was busied
out. WARNING OFF release port UUCSSpp
130(a) None WARNING ON test port UUCSSpp sh
257 Channel
Administration
Memory Array
(CAMA) Test (#205)
MINOR ON te st port UUCSSpp l r 3
17667 In-line error
513 140AY Channel
Sanity Inquiry Test
(#222)
MINOR ON test port UUCSSpp sh r 3
17684 In-line error
769(b) None