DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1159PDATA-PT (Packet Data Line Port)
9
1115 ABORT The PDATA port resources could not be allocated.
1. Run the busyout port UUCSSpp
2. Run the test again
3. Retry the command at 1-minute intervals for a maximum of 3 times.
4. Release the port when done.
2012 ABORT System Call Failed
2031 ABORT Uplink messages software failed.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals for a maximum of 3 times.
7 FAIL Wiring does not match ad ministration.
8 FAIL Invalid test message sequence.
10 FAIL Data Line port did not reset correctly.
11 FAIL PDATA port Data Terminal Ready (DTR) did not reset correctly.
12 FAIL PDATA port did not reset correctly.
2000 FAIL Test timed out, most probably the administered ports are not connected
correctly. For the above failure codes, use the following steps to correct the
problem.
1. Enter the commands list data-module and status data-module
extension on the G3-MT to find the corresponding Data Line port number
and PDATA port number. Check the wiring between the PDATA port and
the Data Line port. Look for loose connections, mis-wiring or broken wires.
2. Retry test a maximum of 2 times, no need to wait between tests.
3. If the test still fails, and the other ports on the circuit pack are not in use,
enter reset board UUCSS. (Use status data-module extension or LED
indicators to determine if other ports are idle).
4. Retry test a maximum of 2 times.
5. Replace the PDATA board.
6. Retry test a maximum of 2 times.
7. Replace the Data Line circuit pack.
8. Retry test a maximum of 2 times.
PASS The PDATA port and the Data Line port of the System Port feature are wired
together as administered.
Table 9-460. TEST #603 System Port Connectivity Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page