DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-405CLSFY-PT (Call Classifier Port)
9
CLSFY-PT (Call Classifier Port)
The TN744 Call Classifier is a service circuit pac k that provides spec ialized tone
detection cap abilities to support the Outb ound Call Management (OCM) and
Inbound Call Management (IC M) features. The TN744 supports both A-law and
Mu-law companding .
The TN744 has eight ports (CLSFY-PTs), each capab le of supporting c all
classification, touch-tone rec eption and MFC-tone generation and d etection. The
CLSFY-PT maintenance object imp lements a set of tests designed to ensure
proper operation of the Call Class ifier.
Error Log Entries and Test to Clear Values
Notes:
a. There are two possible alarm levels for this error typ e: MAJOR and
MINOR. A major alarm is raised if the total number of c all classifier ports
currently in-service is less than or eq ual to 1/2 of the administered
MO Name (in
Alarm Log) Alarm
Level Initial Command to
Run1
1. UU is the universal cabine t number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
CLSFY-PT1MAJOR test port UUCSSpp sh Call Classifier Port
CLSFY-PT MINOR test port UUCSSpp sh Call Classifier Port
CLSFY-PT WARNING test port UUCSSpp sh Call Classifier Port
Table 9-171. Call Classifier Port (CLSFY-PT) Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
1 any Tone Detector
Audit/Update Test (#43) MAJOR/
MINOR(a) ON test port UUC SSpp r 2
18 busyout port WARNING OFF release port UUCSSpp
257(b) 17666 Tone Detection Audit
Update Test (#43) MAJOR/
MINOR(a) ON test port UUC SSpp r 3
513(c) any Tone Detection Verification
Test (#42) MAJOR/
MINOR(a) ON test port UUC SSpp r 3