DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-343BRI-SET, ASAI-ADJ, BRI-DAT
9
50 Requested
Facility Not
Subsc ribe d
Requested facility is imp lemented, but not
administered. Potential administra tion problem
with endpoint or adjunc t. For BRI endpoints:
1. Verify the switch administration of endp oint
using either the display station or display
data-module commands.
2. If Step 1 does not resolve the problem, refer
to the endpoint’s servic e manual and verify
administration on the endp oint.
3. If Step 2 does not resolve the proble m,
escalate to the next tier.
For ASAI adjuncts:
1. Display the Customer Optional Features
Form (administration screen) on the switc h
to determine which ASAI cap abilities are
turned on in the switch.
2. Verify that the adjunct is administered to
support the identic al capabilities as the
switch. If there is a mismatch in the
administered cap abilities, then readminister
the switch and/or the adju nct to establish a
consistent set of desired capabilities on
both the switch and the ad junct.
3. If Step 2 does not resolve the proble m,
escalate to the next tier.
For Lucent adjuncts:
1. Display the Customer Optional Features
Form (administration screen) on the switc h
to determine if the Lucent ad junct is set
enabled on in the switch.
2. If error type 2567 or 2568, verify the Lucent
adjunct version, and readmi ni ste r if
needed.
3. If step 2 does not fix the p roblem, escalate
to the next tier of support
Table 9-150. ISDN-BRI CAUSE VALUES — Continued
Error
Code Test Result Description/ Recommendation
Continued on next page