DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-409CLSFY-PT (Call Classifier Port)
9
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not alloc ate the necessary system resourc es to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL Hardware audit failed.
1. Issue these commands in order: busyout board, reset board, release
board. The board reset is required to reload on-board RAM associated
with the TN744’s DSPs. T his takes all 8 tone detector ports out of service
for a few seconds. Only 4 of the 8 would be out of service due to the
alarm. (There are 5 tone detectors on each of the two DSPs.) Other than
the unlikely potential of running out of tone detector resources in the
switch, there is no other effect when the board is reset.
2. Test the board (test board UUCSS long).
3. If the test still fails, replace the board.
PASS The call classifier port has passed the sanity inquiry.
Table 9-173. TEST #43 Tone Detector Audit/Update Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page