DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-101ANN-BD (Announcement Circuit Pack)
9
Notes:
a. Error Type 1This error indicates the circuit pac k totally stopped
functioning or it was physic ally removed from the system.
NOTE:
The alarm is logged ab out 11-minutes after the circuit pac k has
been removed or when the SAKI Test (#53) fails.
If the circuit pac k is not in the system, insert a circuit p ack (in the same
slot as the error indicates) to resolve this error. If the c ircuit pack is in the
system and the red LED is on, refer to ‘‘LED Alarms without Alarm Log
Entry or with Error Type 1’’
in Chapter 7, ‘‘LED Interpretation’’.
b. Error Type 14This error is logged whenever the Announcement
Checksum Test (#209) fails. The Aux Data indicates the identifying number
of the first defective announc ement found. This number correspond s to
the announcement numbers on the announc ement administration form.
The extension associated with the announc ement can be determ ined with
the display announcement command. This error always app ears in
conjunction with Error Type 2817. Follow the procedures for Error Type
2817 to troubleshoot Error Type 14.
c. Error Type 23The circuit pack has b een logically admi nistered but not
physically installed. The alarm c lears when the circuit pac k is installed.
17676 In-line Error
2817(j) Announcement
Checksum Test
(#209)
MINOR ON test board UUCSS sh r 3
17682 In-line Error
17699(j) In-line Error
3840(l) Any None
3999 (o) Any None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 9-38. Announcement Circuit Pack Error Log Entries — Continued
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value
Continued on next page