DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-136ASAI-PT
9
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or whe n the BRI
circuit pack d etects that Level 1 has been deactivated on the p ort. The
Aux Data field contains one of the following values:
Refer to the repair procedures for Test #621.
b. The circuit pac k is having problems transm itting data to the Packet Bus,
thus affecting the conveyanc e of signalling information over D-channel.
This error occurs when the Packet Bus transmit FIFO buffer overflows. This
condition probab ly indicates a hard ware problem as well. The ASAI-PORT
alarm level is MAJOR with aux data 0. Use troubleshooting procedures for
both on-board hardware p roblems and poten tial off-board Packet Bus
problems.
Table 9-53. ASAI-PT Port Error Log Entries
Error
Type Aux
Data Associated Test Alarm Level
ASAI-PORT On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) (a) Level 1 Status
Inquiry (#621) MAJ2
2. Major and Minor alarms may be downgraded to warning alarms based on the value used in the set
options command.
OFF test port UUCSSpp sh r 2
513 (b) 0 none (b) ON
1537 (c) 46210 CRC Error
Counter (#623) MAJ2OFF
3841 (d) 46208 None
3844 (e) 46223 None
3845 (f) 46211 None
3846 (g) TEI None
Continued on next page
Blank This indicates that the Level 1 Status Inquiry failed .
32773 This is a message from the ASAI-Line circuit p ack indicating
Level 1 has been deactivated.