DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1375SN-CONF (Switch Node Configuration)
9
d. The physical neighbor typ e does not match administrati on. If the aux data
is 1, the type of neighbor ad ministered is an SNI and the type of neig hbor
connected is an EI. If the aux data is 2, the type of neighbor ad ministered
is an EI and the type of neighb or connected is an SNI.
To resolve error type 6002 with aux data 1, refer to FAIL code 136 for test
759. To resolve error type 6002 with aux data 2, refer to FAIL code 137 for
test 759.
e. The neighbor location does not match administration.
To resolve this error, refer to FAIL code 138 for test 759.
f. A peer link does not exist to another equip ped SNI. The aux data equals
the slot number of the SNI to which this SNI or SNC does not have a p eer
link. To resolve this error, refer to the FAIL code for test 759 corresponding
to the aux data on the following tab le:
g. A link does not exist to one of the SNCs. If the aux data is not 1 or 2, the
link from this SNI to the active SNC does not exist. If the aux data is 1, the
link from this SNC to the active SNC does not exist. If the aux data is 2, the
link from this SNC to the standby SNC does not exist.
To resolve this error, refer to FAIL code 112 for test 759.
h. The SNI is administered to be connected to a DS1C but is not.
To resolve this error, refer to FAIL code 139 for test 759.
Aux Data (slot no.) Test 759 FAIL Code
2102
3103
4104
5105
6106
7107
8108
9109
13 113
14 114
15 115
16 116
17 117
18 118
19 119
20 120