DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1622SYSAM (Circuit Pack)
9
1379 ABORT System could not determine if testing of remote access p ort is administered.
1. Check system-parameters maintenance screen for a y in the Test
Remote Access Port field.
2. Retry the command.
2000 ABORT Response to the test request was not received within the allowable time
period. If the system is a High or Critical Reliability configuration and if the
SYSAM circuit pack is on the standby SPE, this abort code may indicate that
the sta ndby SPE is not r espon ding to the ha ndsha ke mess age. I f this i s the
case, the sta ndby SPE mainte nance softwa re may ta ke up t o two mi nutes t o
indicate that hand shake communication with the s tandby SPE is down. The
ABORT code will then change to 1339 (standby SPE unavailable).
1. Retry the command at 1-minute intervals, a maximum of 3 times.
2034 ABORT The remote access port is busy. A remote user has probably dialed into the
switch.
1. If a remote user is dialed in, remote access line is working. No need to
run test. Use the status logins command to verify that the SYSAM-RMT
port is in use.
2080 FAIL An external modem is administered on a switch with an active TN1648 (prior
to suffix B.)
1. Set the Modem Connection: field on the system-parameters
maintenance screen to internal. (The external modem capab ility requires
a TN1648 suffix B or later.)
2. Retry the command.
Table 9-613. TEST #912 SYSAM External Modem Present Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page