DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-297status port-network
8
Dedicated
Tones This field shows whether the TDM bus has the system tones on it
(“y”/”n” ). Only one TDM bus of a TDM bus pair can have syste m tones on
it at a given time. If the system does not c ontain an EPN, blanks appear
in this field.
TONE/CLOCK The location of the tone-clock c ircuit packs in the sp ecified Port Network.
The location is represented using the cabinet and c arrier where the
tone-clock resides (e.g . 1a, 1b, 2a, 2b, etc .).
Service
State This field represents the operational sta te of the tone-clock circ uit pack.
A service state of "in" means the tone-clock has been installed and is in
normal operation. A service state of "out" means that the tone-clo ck is out
of service and has failed certain maintenance tests.
System
Clock This field shows which tone-clock circuit pack supplies the system cloc k
for that port network by disp laying the mode of the tone-c lock. An
“active” mode means that the tone-clock supplies the system clock. Only
one tone-clock in each Port Network c an have a mode of “ac tive” at any
given time. A “standb y” mode means the tone-c lock is part of a
duplicated clock system and i s ready to supply the sys tem clock, but is
not currently “active.” A “down” mod e means the tone-clock is not
operational.
System
Tones This field shows which tone-clock c ircuit pack sup plies the system tones
for that port network by disp laying the mode of the tone-c lock. An
“active” mode means that the tone-clock supplies the system tones. Only
one tone-clock in each Port Network c an have a mode of “ac tive” at any
given time. A “standb y” mode means the tone-c lock is part of a
duplicated clock system and i s ready to supply system to nes, but is not
currently “active.” A “down” mod e means the tone-clock is not
operational.
PKT This field contains the Packet Bus identi fier, which is the same as the Port
Network number.
Service
State This field represents the operational sta te of the packet bus. A servic e
state of “in” means the p acket bus has been ins talled and is in normal
operation. A service state of “ out” means that the pack et bus is out of
service and has failed c ertain maintenance tests, or the maintenanc e
object has been d emand busied out. A service state of “reconfig ” means
that the Maintenance/Test circuit p ack has swapped one or more signal
leads because of lead faults detected during testing (Dup lex System
Only). A service state of “op en lds” means the Maintenanc e/Test circuit
pack query was run and open bus leads were found. A service state of
Blanks in this field means the system do es not have the Packet Bus
feature optioned.
Major
Alarms Whether major alarms are logged ag ainst the packet bus th at is being
displayed ("y" or "n").
Minor
Alarms Whether minor alarms are logged ag ainst the packet bus th at is being
displayed ("y" or "n").