DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-458DAT-LINE (Data Line Port)
9
Error Log Entries and Test to Clear Values
Notes:
a. This is a software audit error that does not indic ate any hardware
malfunction. Run the Short Test Sequence and investigate errors.
b. Indicates the c ircuit pack has b een removed or has been insane for more
than 11-minutes. To clear the error, reseat or replace the circuit p ack.
c. Error type 769 indicates that the d ata line circuit pac k found an error in the
transmit/receive circuitry of an administered data line when the c ircuit
pack was inserted. Perform the following:
1. Enter busyout board UUCSS for the circuit pack on which the por t
resides.
2. Enter reset board UUCSS. Check the Error Log to determine if
Error Type 769 is logged again for DAT-LINE. Make sure that the
Active Alarms Only field is set to n.
If error type 769 reappears, replac e the data line circuit p ack. If
Error Type 769 does not reappear, proceed to Step 3.
3. Enter release board UUCSS.
Table 9-190. Data Line Port Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test S equence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test port UUCSSpp sh r 1
1 Digital Looparound
Test (#171) MINOR ON test port UUCSSpp s r 2
15(a) Any Audit Update Test
(#36)
18 0 Busyout port
UUCSSpp WARNING OFF rel port UUCSSpp
130 (b) None WARNING ON test port UUCSSpp sh
257 Conferenc e Circuit
Test (#7 ) MINOR ON test port UUCSSpp l r 2
513 NPE Crosstalk Test
(#6) MINOR ON test port UUCSSpp l r 2
769(c) 40983 None