Maintenance Object Repair Procedures
9-64ANL-24-L (24-Port Analog Line)
9
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or have time slots out-of-service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station command to d etermine the service state of the
port. If the port is in use, wait until the port is idle before testing.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
1005 ABORT The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disrup tive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1018 ABORT The test has been disabled by administration. The default for the Test field
on the station form is y. Determine why this field has been set to n on this
station (this may be due to the ringing application Test #48, that can be
customer or terminal disturbing).
1. To enable the test for a particular station being tested, enter change
station extension and set the Test? field on the station from n to y.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run test are not available. This could be due
to a failure to seize the port.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Table 9-27. TEST #6 NPE Crosstalk Test — Continued
Error
Code Test
Result Description/Recommendation
Continued on next page