Maintenance Object Repair Procedures
9-1295PNC-DUP (PNC Duplication)
9
PNC-DUP Related Commands
The following commands and their outp ut screens are fully described in Chapter
8, ‘‘Maintenance Commands’’.
Busyouts and PNC-DUP
Busyout pnc puts the standby PNC in the b usyout state. In this condition:
1. Double call set up is tur ned off.
2. The standby PNC is unrefreshed; existing d uplicate call co nnections are
removed.
3. PNC interchanges are prevented.
Upon release, interchanges are re-enab led and a global refresh of double call
setup on the standby is performed.
When PNC duplication is in effect:
An active PNC component ca nnot be busied-out.
A standby PNC component c an only be busied-out when the standby
PNC is first busied-out.
The standby PNC cannot be released unless all standby PNC
components are released.
status pnc This command displays information about the operational status of
both PNCs including state of health, alarms, busyouts and locks,
and so on.
reset pnc
interchange This command is used to initiate a demand PNC interchange. If the
standby is healthy (state o f health indexes all zero), there is no
effect on service. Otherwise, calls may be dropped.
set pnc This command is used to lock or unlock the active PNC, preventing
interchanges. It does not interfere with double call setup.
busyout pnc This removes the standby PNC from service. See also the follow ing
section on busyout of PNC components.