DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1171PDMODULE (Processor Data Module) TDMODULE (Trunk Data Module)
9
Bad Scan Inquiry A message is sent uplink that contains a c ount
generated by c ertain events relating to the dig ital loop’s (link) cond itions.
This could be an indic ation of communication p roblems between the
processor and digital port board.
EPF inquiry The status of the Electronic Power Feed is sent uplink. EPF
is not used for data modules.
ID Request A request is made to the dat a module for its status. The
data module sends its c onfiguration information and h ealth information
back. This information is chec ked and a pass /fail result is provided.
Ringer Update This updates the data module’s ringer state ac cording
to processor records.
Translation Update This is a message normally used with digital
stations to refresh the default value that caus es the station to send touch
tones only in the primary information c hannel. This test is not used with
data modules.
Table 9-466. TEST #17 Data Module Audits Test
Error
Code Test
Result Description/ Recommendation
1 ABORT Switchhook audit timed out.
1. Verify the data module is connected to the PBX and repeat the test.
2. If the test aborts, replace the data module and repeat the test.
3. If the test continues to abort, replace the circuit pac k and repeat the test.
2 ABORT ID request fails, health bit is defective, or no response from on-board
microprocessor.
1. Verify that the correct data module type (PDM versus TDM) is administered.
2. If the test aborts, replace the data module and repeat the test.
3. If the test aborts, replace the circuit pac k and repeat the test.
3 ABORT No response from EPF audit.
4 ABORT Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page