9-1652TAPE

9
Tape External Loop-around
This test is similar to the Internal Loop-around test exc ept that the data originates in the Host Adapter ’s Dual Port RAM and it is transferred to and from th e SCSI Da ta Memo ry usi ng SPE sys tem b us acc esse s. Onl y a smal l amount of data is sent to the Tape Drive circuit pac k in order to keep system bus access to a min imum.
Table 9-622. TEST #814 Tape Loop-around Test
Error
Code Test
Result Description/ Recommendation
1316 ABORT Could not get access to the Mass Storage System. Other application software
may be using it or background maintenance tests may be running.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, verify that the daily translation-save operation
is not in progress (issue the display system-parameters maintenance
command to display the time for scheduled maintenance and the "y/n"
option for saving translation daily).
1335 ABORT Could not run the test on the Standby SPEDuplication not administered.
1. Refer to the documentation for STBY-SPE maintenance.
2. Administer standby present.
1338 ABORT Could not run the test on the Standby SPEInterchange pending.
1. Refer to the documentation for STBY-SPE maintenance.
2. After interchange occurs, run test on new active SPE.
1339 ABORT Could not run the test on the Standby SPEHandshake down.
1. Refer to the documentation for STBY-SPE maintenance.
2. When the standby is restored to service (use status spe to determine state
of standby) retry the command.
1347 ABORT Could not run the test on the Standby SPERefresh not complete.
1. When the standby is restored to service (use status spe to determine state
of standby) retry the command.
1350 ABORT Could not run the test on the Standby SPEShadowing not enabled.
1. When the standby is restored to service (use status spe to determine state
of standby) retry the command.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2500 ABORT Could not run the test on the Standby SPEInternal software error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page