DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-335BRI-SET, ASAI-ADJ, BRI-DAT
9
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol;
timers associated with cer tain Layer 3 messages have expired b efore a
required response was received . In the following table, the aux d ata field
indicates which timer has just ex pired. (For more information, refer to the
Lucent ISDN-BRI Specification.
2817(i) 0 XID Test (#628) WARNING MAJOR/
WARNING 2OFF test station ext r 2
test data-module
ext r 2
3073(j) 0 BRI Remote
Loop Back
(#627)
WARNING OFF test station ext l r 2
test data-module
ext l r 2
3329
(k) Any Signaling Link
Status
(626)
WARNING MAJOR/
WARNING 2OFF
3584 0,1 None
3585-
3839(i) 0None
3840-
4095
(m)
(n)
0None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
2. Major alarms on this MO may be downgrad ed to Warning alarms b ased on the value used in the
set options command.
Table 9-148. BRI-SET/ASAI-ADJ Error Log Entries — Continued
Error
Type Aux
Data Associated Test
Alarm
Level
BBRI-SET
Alarm
Level
ASAI-ADJ
ASAI-ADJ
ATT-A DJ
LGATE-AJ
ATTE -AJ On/Off
Board Test to Clear Value
Continued on next page