DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-204ATM-EI (Expansion Interface Circuit Pack)
9
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out of serv ice.
1. Resolve any TTR-LEV errors. Even if there are no TTR-LEV errors, there
may not be a Tone Detector available on the network that contains the
circuit pack being tested . Verify that there is at least one Tone Detector
on this network. If there is not at least one Tone Detector, this test always
aborts for this ATM-EI board. This will not harm the system.
NOTE:
DEFINITY Systems require that Tone Clock circuit packs (TN2182)
must be of vintage “B” or newer. If older Tone Detector circuit packs
are installed in the system, this test always aborts with this abort code.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 3 times.
1015 ABORT The ATM-EI circuit pack has not been busied out.
1. Busyout the ATM-Expansion Interface circuit pack, then repeat the test
board UUCSS long command.
1031 ABORT If the ATM Expansion Interface circuit pack is in an EPN and is on the active
PNC, this test cannot be exec uted.
1. If PNC Duplication is enabled, attempt to make the standby PNC active
with the reset pnc interchange command.
2. If the PNC Interchange is successful, rerun the test.
1033 ABORT The ATM-EI circuit pack is not present.
1. Issue the list atm-pnc command to verify that switch recognizes the
circuit pack.
2. Retry the command.
1139 ABORT The packet bus in the EPN where this ATM-EI board is located has a major
alarm against it. This test needs to use the alarmed port network’s Packet
Bus.
1. Resolve any PKT-BUS problems.
2. Retry the command.
1141 ABORT The Packet Interface circuit pack is out of service.
1. Res olve an y PKT-INTF p robl ems.
Table 9-87. ATM Board Framer Looparound Test (#1260) — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page